180 research outputs found

    Leisure-time, occupational, and commuting physical activity and risk of type 2 diabetes in Japanese workers: a cohort study

    Get PDF
    Table S1. Association between moderate-intensity and vigorous-intensity exercise during leisure and risk of type 2 diabetes. Table S2. Risk of type 2 diabetes associated with specific type of leisure-time exercise. (DOCX 47 kb

    Estimation of Newtonian noise from KAGRA cooling system

    Full text link
    KAGRA is the first km-scale gravitational wave detector to be constructed underground and employ cryogenics to cool down its test masses. While the underground location provides a quiet site with low seismic noise, the cooling infrastructure is known to generate large mechanical vibrations due to cryocooler operation and structural resonances of the cryostat. As cooling system components are relatively heavy and in close proximity to the test masses, oscillation of gravity force induced by their vibration, so-called Newtonian noise, could contaminate the detector sensitivity. In this paper, we use the results from vibration analysis of the KAGRA cryostat to estimate cooling system Newtonian noise in the 1-100 Hz frequency band. Our calculations show that, while this noise does not limit the current detector sensitivity or inspiral range, it will be an issue in the future when KAGRA improves its sensitivity. We conclude that KAGRA may need to implement Wiener filters to subtract this noise in the future

    Differences in Velopharyngeal Structure during Speech among Asians Revealed by 3-Tesla Magnetic Resonance Imaging Movie Mode

    Get PDF
    Objective. Different bony structures can affect the function of the velopharyngeal muscles. Asian populations differ morphologically, including the morphologies of their bony structures. The purpose of this study was to compare the velopharyngeal structures during speech in two Asian populations: Japanese and Thai. Methods. Ten healthy Japanese and Thai females (five each) were evaluated with a 3-Tesla (3 T) magnetic resonance imaging (MRI) scanner while they produced vowel-consonant-vowel syllable (/asa/). A gradient-echo sequence, fast low-angle shot with segmented cine and parallel imaging technique was used to obtain sagittal images of the velopharyngeal structures. Results. MRI was carried out in real time during speech production, allowing investigations of the time-to-time changes in the velopharyngeal structures. Thai subjects had a significantly longer hard palate and produced shorter consonant than Japanese subjects. The velum of the Thai participants showed significant thickening during consonant production and their retroglossal space was significantly wider at rest, whereas the dimensional change during task performance was similar in the two populations. Conclusions. The 3 T MRI movie method can be used to investigate velopharyngeal function and diagnose velopharyngeal insufficiency. The racial differences may include differences in skeletal patterns and soft-tissue morphology that result in functional differences for the affected structures

    Heterozygous B beta-chain C-terminal 12 amino acid elongation variant, B beta X462W (Kyoto VI), showed dysfibrinogenemia

    Get PDF
    A heterozygous patient with dysfibrinogenemia with slight bleeding and no thrombotic complications was diagnosed with fibrinogen Kyoto VI (K-VI). To elucidate the genetic mutation(s) and characterize the variant protein, we performed the following experiments and compared with identical and similar variants that have already been reported. The proposita's PCR-amplified DNA was analyzed by sequencing and her purified plasma fibrinogen underwent SDS-PAGE followed by immunoblotting, fibrin polymerization, and scanning electron microscopic observation of fibrin clot and fibers. Sequence analyses showed that K-VI fibrinogen substituted W (TGG) for terminal codon (TAG), resulting in 12 amino acid elongation 462-473 (WSPIRRFLLFCM) in the B beta-chain. Protein analyses indicated that the presence of some albumin-binding variant fibrinogens and a dimeric molecule of variant fibrinogens reduced fibrin polymerization, with a thinner fiber and aberrant fibrin network. These results are almost the same as for the identical variant of Magdeburg, however, different from the similar variant of Osaka VI [ 12 amino acid elongation 462-473 (KSPIRRFLLFCM) in the B beta-chain] in the presence of variant forms and clot structure. We speculate the side-chain difference at 462 residues, W in K-VI, K in Osaka VI, and/or the difference in the presence of disulfide bridged forms of variant fibrinogens, led to the notable difference in the fibrin bundle network. Although a strong evolutional and structural association between B beta-chain and gamma-chain molecules is established, the corresponding recombinant 15 residue elongation variants of the fibrinogen gamma-chain showed reduced assembly and secretion.ArticleBLOOD COAGULATION & FIBRINOLYSIS. 23(1):87-90 (2012)journal articl

    New application of dynamic magnetic resonance imaging for the assessment of deglutitive tongue movement

    Get PDF
    Background: Deglutitive motion of the tongue may function to maintain tooth position. However, the causation between abnormal patterns of orofacial muscle function and dental malocclusion remains unclear. To clarify the pathogenic mechanism of malocclusion, it is important to determine the relative positional relationship between the tongue tip and incisor edge or the dorsal tongue and palate during deglutition. Here, we assessed the utility of 3-T segmented cine-magnetic resonance (MR) imaging, combined with static MR images for hard tissue visualization, in assessing the relationship between the tongue and the surrounding tissues during deglutitive tongue movement. Methods: Cine-MR images were acquired from three healthy female volunteers during deglutition who had no history of swallowing disorder or other chronic illness, normal alignment and occlusion, and a skeletal class I relationship. Three cine-MR images were taken during deglutition in accordance with an auditory cue for each volunteer. During static imaging, custom-made, contrast-medium-filled clear retainers were positioned in the mouth to allow visualization of the upper and lower incisors and hard palate boundaries. Static images were superimposed onto images of the three stages in deglutitive tongue movement, which were selected from a series of cine-MR images. These superimpositions were assessed five times by tracing cephalometric parameters to examine the reproducibility of the method. Results: Traces varied little across repeated measurements, and all subjects had a similar pattern of dorsal tongue movement. Tongue-to-palate contact increased slightly during the first to second stage of swallowing and abruptly increased during the second to third stage, while the tongue tip position remained constant. Conclusions: Segmented cine-MR imaging combined with static MR images is useful for assessing soft tissue motion during deglutition. This method is particularly useful in dentistry to evaluate the relationship between tongue function and maxillofacial morphology in terms of orthodontic treatment and orofacial myofunctional therapy, and for improving tongue movement during speech therapy

    Principles of the magnetic resonance imaging movie method for articulatory movement : a review

    Get PDF
    Magnetic resonance imaging (MRI) has become a critical tool for dental examination. MRI has many advantages over radiographic examination methods, including the lack of a requirement for patient exposure and the ability to capture high-contrast images of various tissue and organ types. However, MRI also has several limitations, including long examination times and the existence of metallic or motion artifacts. A cardiac imaging method using cine sequences was developed in the 1990s. This technique allows for analysis of heart movement and functional blood flow. Moreover, this method has been applied in dentistry. Recent research involving 3T MRI has led to the achievement of a temporal resolution of <10 ms, surpassing the frame rate of typical video recording. The current review introduces the history and principles of the cine sequence method and its application to the oral and maxillofacial regions

    Carcinoma-containing CEA in colon cancers in primary and metastatic tumors

    Get PDF
    Carcinoma-containing CEA was measured as compared with normal tissues and metastases in the lymph nodes and the liver. The high CEA production was remarkable in the potent malignant tumors and metastases in the liver and the lymph nodes as compared with those in normal colon tissues as well as in non metastatic lymph nodes. It is reasonable to consider that high plasma CEA may well indicate advancing or highly potent malignant diseases or recurrence of colon cancers due to destruction of vascular structure by cancer invasion

    Surgery for postoperative recurrence of gastric cancer

    Get PDF
    The six patients who underwent reoperation for recurrence of gastric cancer following surgery were clinically analysed, of whom one had lung metastasis and the other five local recurrences. The conditions of resectability are that carcinoma infiltration should be limited, the disease-free interval-after the first operation should be long and there are no blood-borne metastases into the lung and the liver. The surgical outcome for lung metastasis was pessimistic. It is emphasized that multidisciplinary therapy and early detection are indispensable for improving the surgical outcome in the treatment of recurrence of gastric cancer

    Benefit from omentopexy on bronchial wound healing in performing concurrent esophagectomy

    Get PDF
    The healing process of bronchial wound was compared among wrapping tissues such as pedicled omentum, pericardium, and parietal pleura in terms of the degrees of revascularization of the bronchial artery interrupted by bronchoplasty itself by microangiography, including the circumstances of performing a procedure of esophagectomy. The development of neovascularity was marked and facilitated by omentopexy. The procedure of wrapping by pedicled pericardium and pleura was not so useful for promoting neovascularity as would be expected, and it was almost the same as non-wrapping one. Meanwhile, recanalization by wrapping with free pleura was delayed. When esophagectomy was combined with bronchoplasty, revascularization was apparently retarded. In conclusion, wound healing at bronchial anastomosis was markedly impaired so that omentopexy was recommended for facilitating wound healing at anastomosis
    corecore